Home > One Air Nozzle Saves $960 per Year – How Many Nozzles Could You Use?

One Air Nozzle Saves $960 per Year – How Many Nozzles Could You Use?

Supplier News
article image
logo
1300 787 688

Contact supplier

Your Email * indicates mandatory fields.
image

A cardboard manufacturing facility was using a 3/8” outside diameter (OD) open tube to blow scrap cardboard off a conveyor. This scrap cardboard would occasionally be blown inside the roller area at the end of a conveyor creating a maintenance nightmare that required hours to disassemble and remove. 

To prevent this from occurring they installed another 3/8″ OD open compressed air tube to divert any cardboard headed toward the conveyor roller. The 3/8″ open tubing eliminated the scrap problem, but introduced a few new ones. The open hose is extremely noisy over (100 dBA). It does not comply with OSHA standard CFR 1910.242(b), which requires that a compressed air blow off device may not be dead ended at more than 30 PSIG. The most costly problem though is a 3/8″ open tubing uses a tremendous amount of compressed air.

They were using so much air in the facility that they were draining the system pressure in their facility. Obviously, they were going to replace the open tube withEXAIR 2” Flat Super Air Nozzle. Replacing this open blow off with an intelligent compressed air product, like theHP1125 High Powered Flat Super Air Nozzleor the1104 Super Air Nozzle, would lower the noise level below 83 dBA. Also, those nozzles use significantly less air. They decided to use the model HP1125 for its thin profile to fit into the tight location. The only question was how much air and energy cost would they save. They could have easily installed aDigital Flow Meteron the supply pipe of the open tube to measure the change in flow once the EXAIR nozzle had been installed, but they wanted to try and estimate the air usage.

Using EXAIR’s test data, we know a 3/8″ OD open tube that is 18″ long will flow 68.5 SCFM at 80 PSIG. An HP1125 2″ Flat Super Air Nozzle utilizes 37 SCFM when fed with 80 PSIG inlet pressure. By removing one 3/8″ OD tube the cardboard manufacturer saved 31.5 SCFM of compressed air. With an electrical cost of $0.08 per kWh, compressed air costs $0.25 per 1000 SCF. Saving 31.5 SCFM reduces the manufacturers electrical bill by $0.48 every hour, $3.48 for every 8 hour shift, and $960 per year (250 working days, eight hours a day). If the manufacturer runs two shifts, the savings will double. The simple return on investment for this nozzle is 130 hours! How many projects can you measure a return on investment in hours?

EXAIR intelligent compressed air products are easy to install, safe, and efficient. By installing these products instead of using unsafe open blow offs, your company can save thousands of dollar every year with minimal investment. While saving electrical expenses, we decrease the noise level which makes your production force a nicer place to work. We also comply with OSHA’s standards. Finally, we may be able to design the blow off better to consistently produce the quality product you expect. Call EXAIR today to discuss your application.